Fixes are available
Fix packs for DataPower XML Security Gateway appliances version 4.0.1
Fix packs for DataPower XML Accelerator appliances version 4.0.1
Fix packs for DataPower Integration appliances version 4.0.1
Fix packs for DataPower B2B appliances version 4.0.1
Fix packs for DataPower Low Latency Appliance version 4.0.1
Fix packs for DataPower XML Accelerator appliances version 4.0.2
Fix packs for DataPower XML Security Gateway appliances version 4.0.2
Fix packs for DataPower Integration appliances version 4.0.2
Fix packs for DataPower B2B appliances version 4.0.2
Fix packs for DataPower Low Latency Appliance version 4.0.2
Fix packs for DataPower Low Latency Appliance version 5.0
Fix packs for DataPower B2B appliances version 5.0
Fix packs for DataPower Integration appliances version 5.0
Fix packs for DataPower XML Accelerator appliances version 5.0
Fix packs for DataPower XML Security Gateway appliances version 5.0
Fix packs for DataPower Integration Appliance XI52 Virtual Edition version 5.0
APAR status
Closed as program error.
Error description
The DataPower Web Services Management (WSM) component, used for data collection with ITCAM SOA, creates a WSM record in the WSM buffer that may have missing field values when an error occurs early in the multistep processing. The following fields should be filled in when the values are available: <request-url> <final-url> <webservice> <service-port> <ws-operation> <client>
Local fix
Problem summary
Affected is the use of web services component. The user was intermittently receiving an incomplete WSM record, which contained exclusively fault information, and lacked basic values such as request-url, final-url, or webservice. This behavior was observed in cases where the fault occurred early on in the execution of the request rule, such that the complete WSM record has not yet been created. This resulted in only partial fault information being returned by the existing error rule.
Problem conclusion
The fix is available in 4.0.1.16, 4.0.2.12 and 5.0.0.6 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC89589
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
382
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-17
Closed date
2013-03-04
Last modified date
2013-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.