APAR status
Closed as program error.
Error description
We have noticed that there are some concurrent deploy tests with only one eTPC server where it will call concurrent number of the tpc createVolume command and it will fail with the following return code: CMMVC7017E Login has failed because the maximum number of concurrent CLI sessions has been reached It seems like for each createVolume command the TPC server will create an ssh session to the V7000. In this particular concurrent test the tester is calling createVolume at least 30 times and it will hit this SVC limitation. The information from the SVC message, CMMVC7017E, should be surfaced in the TPC message for the call that failed.
Local fix
none - on failure, investigate TPC logs further
Problem summary
**************************************************************** * USERS AFFECTED: Deployers using the API to connect with TPC * **************************************************************** * PROBLEM DESCRIPTION: See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
The defect should contain the return code 10003 and status -100 for the subjob if we get the ssh limit session. Please be aware that TPC returns a TPCAsyncResult for the entire job that contains sub-results for each sub-job run. In this case, is you want to see the 10003 return code you will need to check the subjob results. The fix for this APAR is targeted for the following maintenance package: | fix pack | 4.2.2-TIV-TPC-FP0004 - target June 2013 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC89105
Reported component name
TPC STANDARD ED
Reported component ID
5608TPCS0
Reported release
422
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-14
Closed date
2013-01-30
Last modified date
2013-01-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC STANDARD ED
Fixed component ID
5608TPCS0
Applicable component levels
R422 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.