APAR status
Closed as program error.
Error description
When observing multiple errors indicating that Tibco EMS objects failed to initialize properly, e.g. "Tibco EMS error(11) - Server not connected Initialization failed" memory growth might be observed in the DataPower appliance, eventually leading to a restart condition.
Local fix
Verify that the configuration of DNS, IP addresses and routing table definitions are all correct for the target Tibco EMS server and allow for proper connectivity and routing of requests between the DataPower device and the Tibco EMS server.
Problem summary
DataPower customers using TIBCO EMS objects are likely to see this problem. Restart might occur if TIBCO EMS objects show Initialization Errors and subsequent to memory growth.
Problem conclusion
The fix is available in 3.8.2.17, 4.0.1.15, 4.0.2.11 and 5.0.0.5 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC88816
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-03
Closed date
2012-12-24
Last modified date
2013-01-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R382 PSY
UP
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022