A fix is available
APAR status
Closed as program error.
Error description
During migration of message flows from toolkit v6.1 to v8.0.0.1, the following error can occur when flows are imported: An internal error occurred during: "Updating message flow ESQL references in 'xxxxxx_xxx'". java.lang.StackOverflowError
Local fix
none available
Problem summary
**************************************************************** USERS AFFECTED: All users of WebSphere Message Broker Toolkit attempting to import V6 or V7 projects containing a large number of message flows that contain references to multiple ESQL modules. Platforms affected: MultiPlatform **************************************************************** PROBLEM SUMMARY: When a user imports flow projects built in the toolkit V6 or V7 containing a number of message flows which contain references to ESQL modules from the compute, filter or other nodes, the migration of the message flows trying to update the references to the ESQL modules may cause a stack overflow error in some use cases.
Problem conclusion
WebSphere Message Broker Toolkit has been modified to handle the use case of ESQL migration from v6 and v7 modules to v8 modules. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Platform v8.0 -------- -------------------- Multiplatforms 8.0.0.2 The latest available maintenance can be obtained from 'WebSphere Message Broker Recommended Fixes' http://www.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available, information on its planned availability can be found in 'WebSphere Message Broker Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IC88593
Reported component name
WEB MB TOOLKIT
Reported component ID
5724J0521
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-28
Closed date
2012-12-20
Last modified date
2012-12-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEB MB TOOLKIT
Fixed component ID
5724J0521
Applicable component levels
R800 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.