  • Closed as program error.

Error description

  • We are unable to use Control Center to monitor our SI processes
    and are having to use man hours to manually check our processes
    24 hours a day.
    

Local fix

  • STRRTC - 355275
    SF / SF
    Circumvention: None
    

Problem summary

  • Description of issue: Queued Activity Monitor showing processes
    for B2Bi servers that have ended.
    

Problem conclusion

  • Description of fix: Only show processes in the Queued Activity
    Monitor for B2Bi servers for which the starting event was seen.
    

Temporary fix

  • Providing a fix to the customer.
    

Comments

APAR Information

  • APAR number

    IC88476

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-21

  • Closed date

    2013-02-15

  • Last modified date

    2013-02-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels

  • R530 PSY

       UP

  • R540 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
15 February 2013