A fix is available
APAR status
Closed as program error.
Error description
In the case of hard failover, a multi-instance standby broker sometimes kills a non-DFE process if the pid matches with the DFE process on the active broker, and later throws BIP2804.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of WebSphere Message Broker. Platforms affected: Linux on Power platform, AIX, HP-UX PA-RISC platform, HP-UX Itanium platform, Linux on x86 platform, Linux on x86-64 platform, Linux on zSeries platform, Solaris x86-64 platform, Solaris SPARC platform **************************************************************** PROBLEM SUMMARY: In the case of hard failover, a multi-instance standby broker sometimes kills a non-DFE process if the pid matches with the DFE process on the active broker, and later throws BIP2804. The same problem may also occur in the case of an operating system crash if the pid of the DataFlowEngine matches with any of the processes started after recovery.
Problem conclusion
WebSphere Message Broker has been modified to check the process command line if it finds a process with a pid matching the one of the DataFlowEngine process on the active machine, or before a crash. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Platform v8.0 -------- -------------------- Multiplatforms 8.0.0.2 The latest available maintenance can be obtained from 'WebSphere Message Broker Recommended Fixes' http://www.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available, information on its planned availability can be found in 'WebSphere Message Broker Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IC88406
Reported component name
WEB MESSAGE BRO
Reported component ID
5724J0520
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-20
Closed date
2012-12-03
Last modified date
2012-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEB MESSAGE BRO
Fixed component ID
5724J0520
Applicable component levels
R800 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.