Error description
Personal Communications v6.0.5 5250 connection The customer receives a negative response error on i5. The negative response is x'10050141'. It means that "Too much data or too little data in a Write Data command". This issue occurs on pcom v6.0.5. Also this issue does not occur on pcom v5.9. Additional symptom: Server received the negative response x'10050121' from the client.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All 5250 display session users * **************************************************************** * PROBLEM DESCRIPTION: Garbage characters display on the 5250 * * emulator screen. * **************************************************************** * RECOMMENDATION: * **************************************************************** When the 5250 session user presses PageUp or PageDown on a screen that needs to restore partial data, garbage characters display in the background. Restored display data is being blocked by a previous fix for a crash issue with non-displayable data.
Problem conclusion
PCSLT52.DLL has been updated with a conditional statement to allow function keys to pass the restore data buffer. Fix scheduled for PCOM 6.0.6 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC88382
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-19
Closed date
2012-11-28
Last modified date
2012-12-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSLT52
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R601 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
06 January 2022