Error description
SONAS system probe is not working correctly. At some point the probe calls (on the device) the following cli command. "cli lsexport -c xxxxx.xxxxx-v -Y -r" According to the documentation, lsexport command "retrieves data regarding the exported folders of the managed clusters from the database and returns a list in either a human-readable format or in a format that can be parsed." When the "control" value from the output of lsexport command is stored in the ACCESS_CONTROL column of TPC T_RES_PROTOCOL_OPTIONS table DB2 SQL Error: SQLCODE=-302, SQLSTATE=22001, SQLERRMC=null, DRIVER=3.62.56 was thrown. Db2 reason: SQL0302N The value of a host variable in the EXECUTE or OPEN statement is too large for its corresponding use. The fix provided, modifies the size of ACCESS_CONTROL column from 256 to 512. Probe example: Found in program files / IBM / TPC / DEVICE/ ... probe log from device ( SONAS system probe ) 2012-10-29 11:27:11.322+0100 HWNEP0001I persisted 50 files set instances 2012-10-29 11:27:11.369+0100 HWNEP0001I persisted 62 files set instances 2012-10-29 11:27:12.447+0100 HWNEP0001I persisted 50 export protocol 2012-10-29 11:27:12.994+0100 HWNEP0002E Log/output file, xxxxxx.xxxxxx._output.txt, not found or failed to load 2012-10-29 11:27:13.010+0100 HWN021709I Perform collection post process tasks for storage system 2012-10-29 11:27:13.010+0100 BTADS0001I Discover Process with Device Server RUN ID xxxx and Job ID xxxxx is complete with Status= 4 , Return Code= 1
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.1.0 and 5.1.1 users * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Upgrade when fix pack is available. * **************************************************************** <span><span>If the CIFS ACL or NFS client list exceeds the length of 256 characters the share protocol options are not properly collected by TPC.</span></span>
Problem conclusion
The fix for this APAR is targeted for the following maintenance package:<br/><br/>| fix pack | 5.1.1-TIV-TPC-FP0001 - target March 2013<br/><br/>http://www-01.ibm.com/support/docview.wss?&uid =swg21320822<br/><br/>The target dates for future fix packs do not represent a formal <br/>commitment by IBM. The dates are subject to change without <br/>notice.
Temporary fix
Comments
APAR Information
APAR number
IC88276
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-16
Closed date
2012-11-19
Last modified date
2012-11-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
data
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R510 PSY
UP
Document Information
Modified date:
23 March 2022