IC88080: CCNS018E MONITOR RATE OUT OF COMPLIANCE. AND CCNS029I MONITOR RATE BACK IN COMPLIANCE OCCURS TOO OFTEN

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • Setting the monitor rest time above one minute on a
    Connect:Enterprise node in Sterling Control Center causes
    CCNS018E Monitor rate out of compliance. and CCNS029I Monitor
    rate back in compliance messages for no reason.
    

Local fix

  • STRRTC - 356361
    SF / SF
    Circumvention: None
    

Problem summary

  • Description of issue:  Frequent erroneous out of compliance
    alerts are issued for CE Unix servers.
    The monitor rest time is specified in units of minutes (all
    other server types use seconds).
    The method which determines if a server is out of compliance
    always assumes monitor rest time is in seconds.
    

Problem conclusion

  • Description of fix:  If the server type is CE Unix, convert
    monitor rest time to seconds when determining if the server is
    in/out of compliance.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC88080

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-08

  • Closed date

    2012-12-06

  • Last modified date

    2012-12-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels

  • R52X PSY

       UP

  • R530 PSY

       UP

  • R540 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Sterling Control Center

Software version:

5.3

Reference #:

IC88080

Modified date:

2012-12-06

Translate my page

Machine Translation

Content navigation