IBM Support

IC88032: PROCESSING XML INPUT IN WSP WITH TRANSFORM BINARY ACTION FROM INPUT CONTEXT RESULTS IN PARSE ERROR FOR REQUEST SIZES > 4KB

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Processing XML input with Transform Binary action from INPUT
    context in a Web Service Proxy results in parse error for
    request sizes greater than 4KB.
    
    This issue occurs when there is Transform Binary action with
    input context of INPUT in a Web Service Proxy rule.
    

Local fix

  • To work arund this issue:
    
    1) Insert a "normal" Transform action (with
        store:///identity.xsl) before the Transform Binary action
    2) Configure the new Transform action as follows:
        * set input context INPUT
        * set output context to PIPE
    3) Change input context of Transform Binary action to PIPE
    

Problem summary

  • Affected is the use of a Web Service Proxy with a Transform
    Binary action.
    
    In case the input context of the Transform Binary action is
    INPUT and request size is greater than 4KB, a parse error
    occurs.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC88032

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-08

  • Closed date

    2013-02-04

  • Last modified date

    2013-03-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R401 PSY

       UP

  • R402 PSY

       UP

  • R500 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022