Fixes are available
Fix packs for DataPower XML Security Gateway appliances version 3.8.2
Fix packs for DataPower Integration appliances version 3.8.2
Fix packs for DataPower B2B Appliance XB60 version 3.8.2
Fix packs for DataPower Low Latency Appliance version 3.8.2
Fix packs for DataPower XML Security Gateway appliances version 4.0.1
Fix packs for DataPower Integration appliances version 4.0.1
Fix packs for DataPower B2B appliances version 4.0.1
Fix packs for DataPower Low Latency Appliance version 4.0.1
Fix packs for DataPower XML Security Gateway appliances version 4.0.2
Fix packs for DataPower Integration appliances version 4.0.2
Fix packs for DataPower B2B appliances version 4.0.2
Fix packs for DataPower Low Latency Appliance version 4.0.2
Fix packs for DataPower Service Gateway appliances version 4.0.2
Fix packs for DataPower Low Latency Appliance version 5.0
Fix packs for DataPower B2B appliances version 5.0
Fix packs for DataPower Integration appliances version 5.0
Fix packs for DataPower XML Security Gateway appliances version 5.0
Fix packs for DataPower Service Gateway appliances version 5.0
Fix packs for DataPower Service Gateway XG45 Virtual Edition version 5.0
Fix packs for DataPower Integration Appliance XI52 Virtual Edition version 5.0
APAR status
Closed as program error.
Error description
If the DataPower uptime wraps while message counts are being monitored for IP's with long delays between logins, SLM can trigger when its message count has not actually been reached. The symptom will be intermittent, obviously incorrect SLM triggering, shutting out an IP which has not exceeded its message count limit.
Local fix
A possible workaround is to restart the DataPower appliance periodically to reset the Uptime: every 24 days for an XI50 or every 49 days for an XI52.
Problem summary
Affected is the use of count monitors. Count monitors might get triggered even though the actual traffic is coming at a rate significantly below the specific rate limit. This happens when you are trying to sending a series of transactions that pass certain points of times (about every 25 or 50 days, depending on firmware releases). Once triggered, all following transactions will be rejected. It will not recover without a shutdown reload.
Problem conclusion
The fix is available in 3.8.2.16, 4.0.1.14, 4.0.2.10, 5.0.0.4 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC86817
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
401
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-25
Closed date
2012-11-13
Last modified date
2012-11-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R382 PSN
UP
R401 PSN
UP
R402 PSN
UP
R500 PSN
UP
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.