IC86809: ERROR LCPR001I ON RESTART OF A BINARY TRANSFER FROM CONNECT:DIRECT Z/OS TO CONNECT:DIRECT WINDOWS


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Connect:Direct z/OS is trying to send a file to Connect:Direct
    Windows in binary mode with a source BLKSIZE greater than the
    default (23040). After the initial session got lost before any
    data was written to the Windows destination file, the restart
    failed with LCPR001I:  Rec len in Comm buffer bigger than IO
    buffer size.
    

Local fix

  • STRRTC - 350522
    MM/MM
    Circumvention: None
    

Problem summary

  • Users Affected:
    Sterling Connect:Direct for Windows 4.4.00
    Sterling Connect:Direct for Windows 4.4.01
    Sterling Connect:Direct for Windows 4.5.00
    Sterling Connect:Direct for Windows 4.5.01
    Sterling Connect:Direct for Windows 4.6.0
    
    Problem Description:
    Connect:Direct z/OS is trying to send a file to Connect:Direct
    Windows in binary mode with a source BLKSIZE greater than the
    default (23040). After the initial session got lost before any
    data was written to the Windows destination file, the restart
    failed with LCPR001I:
    Rec len in Comm buffer bigger than I/O buffer size.
    

Problem conclusion

  • Resolution Summary:
    Modified the calculation of the IO buffer size at the restart.
    
    Delivered In:
    Sterling Connect:Direct for Windows 4.4.00 Build 069 Fix 151
    Sterling Connect:Direct for Windows 4.4.01 Build 012 Fix 39
    Sterling Connect:Direct for Windows 4.5.00 Build 051 Fix 89
    Sterling Connect:Direct for Windows 4.5.01 Build 017 Fix 55
    Sterling Connect:Direct for Windows 4.6.0.2_iFix012
    

Temporary fix

  • Workaround: specify a destination blocksize for Windows in the
    COPY step, like "TO (... DCB=(BLKSIZE=27998))"
    

Comments

APAR Information

  • APAR number

    IC86809

  • Reported component name

    STR CD FOR WIND

  • Reported component ID

    5725C9908

  • Reported release

    450

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-25

  • Closed date

    2012-11-29

  • Last modified date

    2012-11-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CD FOR WIND

  • Fixed component ID

    5725C9908

Applicable component levels

  • R460 PSY

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Sterling Connect:Direct


Software version:
4.5


Reference #:
IC86809


Modified date:
2012-11-29

Translate my page