IC86449: FILES CAN BE MODIFIED BY OTHER USERS EVEN THOUGH PERMISSIONS ARE SET TO RESTRICT THEIR ACCESS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • Error Description￘
    On AIX platforms files can be modified by other users even
    though permissions are set to restrict their access when using
    Connect Direct.
    

Local fix

  • Local Fix￘
    STRRTC - STSDUR,146
    SD/SD
    No workaround available
    

Problem summary

  • Users Affected:
    Sterling Connect:Direct for UNIX 3.8.00
    Sterling Connect:Direct for UNIX 4.0.00
    Sterling Connect:Direct for UNIX 4.1.0
    Problem Description:
    On AIX 6.1 and above, a copy step that overwrites a local file
    to which the local user has no update permission is successful.
    Platforms Affected:
    AIX
    

Problem conclusion

  • Resolution Summary:
    Fixed code so that on AIX 6.1 and above, a copy step that
    overwrites a local file to which the local user has no update
    permission fails appropriately.
    Delivered In:
    Sterling Connect:Direct for UNIX 4.0.00 fix 104
    Sterling Connect:Direct for UNIX 4.1.0.3 iFix007
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC86449

  • Reported component name

    STR CD FOR UNIX

  • Reported component ID

    5725C9907

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-10

  • Closed date

    2012-10-05

  • Last modified date

    2013-01-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CD FOR UNIX

  • Fixed component ID

    5725C9907

Applicable component levels

  • R380 PSY

       UP

  • R400 PSY

       UP

  • R410 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Sterling Connect:Direct

Software version:

4.0

Reference #:

IC86449

Modified date:

2013-01-24

Translate my page

Machine Translation

Content navigation