IC86419: SLOW RESPONSE TIME OF ACTIVE ALERTS AFTER UPGRADING TO 5.3

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The first time the active alerts window is opened it takes
    minutes to display the alerts.
    

Local fix

  • STRRTC - 341535
    SF / SF
    Circumvention: None
    

Problem summary

  • Description of issue: When the alerts are displayed, the alert
    icon display changes based on whether that alert has any
    comments associated with it  or not.
    The calls were made to the engine/database once for each alert
    and then that value was cached on the UI, causing a delay in the
    GUI response.
    

Problem conclusion

  • Description of fix:  Change has been made to avoid that
    engine/database calls while displaying the alerts but it will
    still display the correct icon.
    

Temporary fix

  • Awaiting customer fix verification.
    

Comments

APAR Information

  • APAR number

    IC86419

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-07

  • Closed date

    2012-10-31

  • Last modified date

    2012-10-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels

  • R530 PSY

       UP

  • R540 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Sterling Control Center

Software version:

5.3

Reference #:

IC86419

Modified date:

2012-10-31

Translate my page

Machine Translation

Content navigation