A fix is available
APAR status
Closed as program error.
Error description
None of the execution groups or the HTTP Listener process were being started by the bipbroker process. This was due to a problem with getting the lock used by the HTTP Listener but no errors are written in the system log.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of WebSphere Message Broker V7.0 and HTTP nodes. Platforms affected: MultiPlatform, z/OS **************************************************************** PROBLEM SUMMARY: On broker startup, none of the execution groups nor the HTTP Listener process were being started by the bipbroker process. This was due to a problem with getting the configuration lock used by the HTTP Listener, but no errors were written in the system log to indicate a problem. The lock used was system-wide and may have been being held by any other broker on the system.
Problem conclusion
WebSphere Message Broker has been modified so that the bipbroker process does not wait indefinitely for the HTTP Listener configuration lock. It will timeout after 60 seconds, write an error to the system log, and continue. In addition, the scope of the lock has been changed to be broker-wide instead of system-wide, to avoid contention with other brokers. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Platform v7.0 -------- -------------------- Multiplatforms 7.0.0.6 Platform v8.0 -------- -------------------- Multiplatforms 8.0.0.2 The latest available maintenance can be obtained from 'WebSphere Message Broker Recommended Fixes' http://www.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available, information on its planned availability can be found in 'WebSphere Message Broker Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IC85861
Reported component name
WEB MESSAGE BRO
Reported component ID
5724J0510
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-13
Closed date
2012-12-10
Last modified date
2012-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEB MESSAGE BRO
Fixed component ID
5724J0510
Applicable component levels
R700 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.