APAR status
Closed as program error.
Error description
A stylesheet evaluating the expression "dp:variable(...) + 1" will restart the appliance for an undefined dp:variable in case of "XSLT 2.0" XSLT processor mode. Removing the "+ 1" the appliance will error appropriately and does not restart.
Local fix
Local Fix￘ In case of "XSLT 2.0" XSLT processing mode, conditionally test the output of the variable before attempting to preform any arithmetic.
Problem summary
Affected are customers using the DataPower XSLT processor in "XSLT 2.0" processing mode. In case a DataPower variable is undefined (NULL), evaluating an arithmetic expression like "dp:variable(...) + 1" will restart the appliance.
Problem conclusion
Fix is available in 3.8.2.15, 4.0.1.13, 4.0.2.9 and 5.0.0.3 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC85116
Reported component name
DATAPOWER BLAD
Reported component ID
DPBLADE01
Reported release
402
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-05
Closed date
2012-09-10
Last modified date
2013-01-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER BLAD
Fixed component ID
DPBLADE01
Applicable component levels
R382 PSY
UP
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFGB5","label":"WebSphere DataPower Integration Blade XI50B"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
07 January 2013