Skip to main content

IC84680: MULTI GM FEATURE DOES NOT WORK WITH TPC-R IF MM LICENSE IS NOT APPLIED.


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Multi GM feature does not work with TPC-R if the MM license
    is not applied. The issue is TPC-R is looking for the wrong bit
    to enable the Multi GM feature.
    

Local fix

  • Install MM license on the hardware
    

Problem summary

  • After upgrading to the 4.2.2.2 release, an attempt to start
    multiple TPC-R Global Mirror sessions on the same DS8000 storage
    system with the multiple Global Mirror feature, will fail. Only
    one Global Mirror session will start successfully and form
    consistency groups. The other sessions will go into a SEVERE
    status indicating they were not able to start the Global Mirror
    processing because there are too many Master relationships on
    the hardware.
    

Problem conclusion

  • The code will now check for the correct feature code.
    

Temporary fix

Comments

  • | MDVREGR 4.2.2-TIV-TPC-FP0002 |
    

APAR Information

  • APAR number

    IC84680

  • Reported component name

    TPC FOR REPL SE

  • Reported component ID

    5608TRMSV

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / Serviceability

  • Submitted date

    2012-06-18

  • Closed date

    2012-07-25

  • Last modified date

    2013-01-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC FOR REPL SE

  • Fixed component ID

    5608TRMSV

Applicable component levels

  • R420 PSY

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Tivoli Storage Productivity Center for Replication


Software version:
420


Reference #:
IC84680


Modified date:
2013-01-28

Translate my page

Content navigation