Error description

  • Error Description
    Using Sterling B2B Integrator 5.1 5102.   The SFTP Server
    banner message cannot be disabled.  Trying to specify
    sftp.properties.BannerMessage= cannot be disabled. Some trading
    partners cannot connect.
    

Local fix

  • Local Fix
    STTBIN - 330946
    TB / TB
    Circumvention: None
    

Problem summary

  • Users Affected:
    SFTP Server users
    
    Problem Description:
    The SFTP Server banner message (sftp.properties.BannerMessage=)
    cannot be disabled. When Blanking out this property, the Server
    uses the default Banner.  Some of the SFTP clients were not
    able to establish connections with the Sterling B2B Integrator
    SFTP Server, since the server is always returning the banner
    message.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    If the BannerMessage property is blanked out in sftp.properties,
    no Banner will be shown to SFTP Clients. (Eg., BannerMessage=)
    If the BannerMessage property is initialized with a string, it
    will be sent to the SFTP client. If this property is missing,
    the default banner will be displayed to the SFTP Client.
    
    Delivered in:
    5104
    5020500
    

Temporary fix

Comments

  • Published 3/4/2013
    

APAR Information

  • APAR number

    IC83915

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-04

  • Closed date

    2012-06-27

  • Last modified date

    2014-11-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • SFTP
    

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R510 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]