Fixes are available
4.2.2 Fix Pack 7 (July 2014) for Tivoli Storage Productivity Center
4.2.2 Interim Fix 2 (December 2012) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 8 (March 2015) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 9 (May 2015) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 10 (August 2015) for Tivoli Storage Productivity Center
4.2.2 Fix Pack 3 (October 2012) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
Get PM report via getrpt cmd from 2 different TPC servers had inconsistent daily 24-hour data output. The way the get PM report for 24-hour period suppose to work for 4.2.1 and prior to 4.2.1 are as follows: * If requested perf report from 12 AM for 24 hours (12 AM to 11:59PM) for that day. The output of getrpt cmd (or gui output) would depend on where the getrpt is run (or if the gui is remote or local to TPC server) * If getrpt/gui is run from the same timezone as the server, then only one day of data is shown (12 AM to 11:59 PM). * However, if getrpt/gui is run from a computer that is in a different timezone than the TPC server, then the 24 hour data really spans 2 days. * In TPC 4.2, the output would show 2 days of data due to the 24-hour spans more than one day (say from 3 AM to 2:59AM the next day, if timezone difference is 3 hours). * Prior to 4.2, output would only shown one day, no cross over to next (or prior) day.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: TPC 4.2.2 and earlier users * **************************************************************** * PROBLEM DESCRIPTION: When a report is generated from two * * TPC servers with the same performance * * data, situated in different time * * zones, the report output is slightly * * different. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
The reports should be in sync. The fix for this APAR is targeted for the following maintenance package: | fix pack | 4.2.2-TIV-TPC-FP0003 - target October 2012 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC83459
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
41W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-15
Closed date
2012-07-12
Last modified date
2012-07-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R42A PSY
UP
R42L PSY
UP
R42W PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB5","label":"Tivoli Storage Productivity Center for Data"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"41W"}]