IC82894: AS2 OUTBOUND COMMUNICATION FAILS AFTER CA CERTIFICATES ARE REMOVED

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • AS2 outbound communication fails for a trading partner
    that points to a removed CA certificate.
    The AS2SendAndProcessSyncMDN business process fails with an
    error in the HTTP Begin Session Service which indicates
    a mandatory parameter for the service is missing.
    The Service Status report contains the message:
    SSL authentication is required, CA Certificate ID is undefined
    in WFC and TP profile contains empty CA System certificate.
    

Local fix

  • Local Fix
    RTC - 323120
    TB / TB
    Circumvention: A possible work around is to edit the AS2
    Partner Profile and save the CA certificates making no changes.
    

Problem summary

  • Users Affected:
    All
    
    Problem Description:
    AS2 outbound communication fails after CA certificates are
    removed.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    Implemented logic to skip the null CA.
    
    Delivered In:
    5104,5010
    

Temporary fix

  • As a workaround customer can remove the null cert from the AS2
    profile.
    

Comments

  • Published 6/20/12
    

APAR Information

  • APAR number

    IC82894

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-24

  • Closed date

    2012-05-25

  • Last modified date

    2012-11-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R500 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Sterling B2B Integrator

Software version:

5.0

Reference #:

IC82894

Modified date:

2012-11-14

Translate my page

Machine Translation

Content navigation