APAR status
Closed as program error.
Error description
Error Description WSMQ Aysnc Receive adapter and WSMQ adapter in async mode do not shutdown properly when an error is encountered on GET. When an error is encountered, the adapters try to connect according to the adapter settings and then enter the shutdown steps but they do not shutdown. They remain in state 'stopping'. WSMQ Aync rec adapter log shows message 'thread stopped' but adapter 'hangs' in state stopping [2012-03-28 18:26:16.919] ALL <WSMQAsyncRcv-LM_WSMQ_ASYNC_REC-1691012981> ### Starting failure workflow [2012-03-28 18:26:17.269] ERROR <WSMQAsyncRcv-LM_WSMQ_ASYNC_REC-1691012981> ### Retry limit exceeded - exiting ### [2012-03-28 18:26:17.269] ALL <WSMQAsyncRcv-LM_WSMQ_ASYNC_REC-1691012981> ### WSMQAsyncRcv thread stopped ### System log eve shows 'has been shutdown' message [2012-03-28 18:26:09.666] ALL Adapter LM_WSMQ_ASYNC_REC is up running [2012-03-28 18:26:44.815] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:26:57.734] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:26:58.144] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:27:20.791] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:27:26.074] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:27:39.644] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:27:39.863] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:28:00.835] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:29:42.969] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:32:47.902] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown [2012-03-28 18:36:15.151] ALL Adapter LM_WSMQ_ASYNC_REC has been shutdown
Local fix
Local Fix STRRTC - 320400 LM / LM Circumvention: Stop and Restart SI
Problem summary
Users Affected: All Users Problem Description: WSMQ Adapter in async mode do not shutdown properly when an error is encountered on GET. Platforms Affected: All
Problem conclusion
WSMQ Adapter in async mode does not shutdown properly when an error is encountered on GET. Resolution Summary: WSMQ Adapter is made to shutdown properly when an error is encountered on GET Delivered In: 5020300, 5020500
Temporary fix
Comments
APAR Information
APAR number
IC82634
Reported component name
STR FILE GATEWA
Reported component ID
5725D0700
Reported release
223
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-04-12
Closed date
2012-07-26
Last modified date
2014-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR FILE GATEWA
Fixed component ID
5725D0700
Applicable component levels
R224 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4TGX","label":"IBM Sterling File Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
12 December 2014