Error description
It is possible to define a replicate, mastered or not, on tables whose primary key definitions have differing fields. This can be different columns (by name), types and even number of fields. If you're lucky this will surface similar to following when synchronizing the replicate, but this depends on the general table schema (when internal checks are satisfied this problem might as well go unnoticed): Starting synchronization scan for replicate tx_repl_g_al117t Error in cmpCol SQL types do not match for c(108) s(103) command failed -- Source and Target do not have the same data type (202) ... or ... command failed -- table column undefined (3) Error Details: SQLCODE:-217 Server g_al117s and table tx:Column (ifx_erkey_1) not found in any table in the query (or SLV is undefined). Having differing primary key definitions might be acceptable when relying on --erkey, but then the synchronization shouldn't fail.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * ER customers on 11.70 * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-11.70.xC5 * ****************************************************************
Problem conclusion
Problem Fixed In IDS-11.70.xC5
Temporary fix
Comments
For download information, go to: http://www.ibm.com/support/fixcentral
APAR Information
APAR number
IC82354
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
B50
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-03-29
Closed date
2012-10-31
Last modified date
2012-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
RA10 PSN
UP
RA10 PSY
UP
RB10 PSN
UP
RB10 PSY
UP
RB50 PSN
UP
RB50 PSY
UP
RB70 PSN
UP
RB70 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.