APAR status
Closed as program error.
Error description
You have PDQPRIORITY set to 1 or higher. You have STMT_CACHE enabled. You run this select statement multiple times: select * from sysdri ( in sysmaster ) Data is returned for the first several runs depending on the STMT_CACHE_HITS setting but subsequent runs return no rows. If you restart the database server then the behavior is reset. You run one or both of these multiple times: onpload job onpladm job The jobs run successfully for the first several runs but subsequent runs return errors like these: Error accessing table 'sysdri', SQL error 100, ISAM error 0 Error occured at HPL failpoint: 11431 Error occured at HPL failpoint: 11008
Local fix
Restart the database server. Do not run any of these with PDQPRIORITY enabled: onpload onpladm select * from sysdri
Problem summary
**************************************************************** * USERS AFFECTED: * * PDQPRIORITY set to 1 or higher, STMT_CACHE enabled or SPL * * and query uses bit vector it can give incorrect results * **************************************************************** * PROBLEM DESCRIPTION: * * PDQPRIORITY set to 1 or higher, STMT_CACHE enabled or SPL * * and query uses bit vector it can give incorrect results due * * to that wrong filter processing. * **************************************************************** * RECOMMENDATION: * * Update to IDS-11.70.xC5 * ****************************************************************
Problem conclusion
Problem Fixed In IDS-11.70.xC5
Temporary fix
Comments
For download information, go to: http://www.ibm.com/support/fixcentral
APAR Information
APAR number
IC82288
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-03-27
Closed date
2012-10-31
Last modified date
2012-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
RB70 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.