IBM Support

IC81530: (CD) ERROR: OUT OF MEMORY ERROR - APPLICATION TERMINATES IMMEDIATELY.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error DescriptionÏ
    Application terminates - Heap dump provided by the Customer.
    When using IBM's heap dump analyzer and found that 800MB of
    memory was used in one StringBuffer in
    com/sterlingommerce/cd/pas/common/PasLogMediator.
    

Local fix

  • Local FixÏ
    Patch 2 was provided to the user.  Files: SSP3400cm.Patch2.tar,
    SSP3400.Patch2.tar
    

Problem summary

  • Users Affected:
    All who run IBM Sterling Secure Proxy 3.4.00 with fix
    
    RTC140683 applied Problem Description:
    
    RTC314343 - Out of memory error during C:D sessions
    Customer applied fix RTC140683 for CD sessions and began to get
    Java Out of Memory errors within 24 hours.
    Fix RTC140683 did some cleanup on the session tracing, but
    introduced a problem where a trace buffer was never written and
    never cleared and grew to over 800MB.
    
    
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Resolution Summary:
    RTC314343 - the code that kept the trace buffer from being
    written and cleared. Delivered In:
    3.2.0.16,3.3.1.19,3.4.0.2,3.4.1.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC81530

  • Reported component name

    STR SECURE PROX

  • Reported component ID

    5725D0300

  • Reported release

    340

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-02-20

  • Closed date

    2012-07-17

  • Last modified date

    2012-07-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR SECURE PROX

  • Fixed component ID

    5725D0300

Applicable component levels

  • R320 PSY

       UP

  • R331 PSY

       UP

  • R340 PSY

       UP

  • R341 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS6PNW","label":"IBM Sterling Secure Proxy"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information