Error description
The issue is that the when you look in the job management window the complete time correlates to when the scan completes, not when the scan data is accepted by TPC. The processing time can run for an hour or two. If customer goes off the complete time shown in the management window, they end up overlapping their scans which can result TPC crashing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Those with TPC 4.2.2 or earlier who are * * scanning filesystems on several agent hosts * * at the same time, e.g. when a filesystem * * scan schedule contained many SRA jobs * **************************************************************** * PROBLEM DESCRIPTION: When the filesystem scans were * * finished, the Server had to process * * results from many SRAs at the same * * time. This caused delays in * * processing of the individual scan * * results. It could have been up to 2 * * hours for scan data to be processed * * but the job panel displayed a much * * shorter time. That was actually the * * start and end time that the SRAs * * reported. With this change the server * * now sets the end time when the * * processing is finished. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
With this fix the overall scan time of an individual scan job reflects the actuall time from starting the job until processing of the result has finished. The fix for this APAR is targeted for the following maintenance package: | fix pack | 4.2.2-TIV-TPC-FP0002 - target April 2012 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC80159
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
33W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-12-02
Closed date
2011-12-08
Last modified date
2011-12-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R42A PSY
UP
R42H PSY
UP
R42L PSY
UP
R42S PSY
UP
R42W PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB5","label":"Tivoli Storage Productivity Center for Data"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"33W"}]
Document Information
Modified date:
17 September 2021