Error description
Timestamps in the MQ Everyplace error log do not match the system time. The year is correct but there are problems with the month and time. . Example: 14/10/2011-09:58:22:328 ERROR - Exception occurred in the bridge listener . This test was run on 14/11/2011, not 14/10/2011 as shown in the error log. . Also noted that there is no AM or PM associated with the time.
Local fix
Problem summary
Since JANUARY was assigned a zero value, all the month values used to be the one preceding the correct month. The time value did not take AM/PM into consideration while displaying the log output.
Problem conclusion
The fix ensures that JANUARY is assigned value one and time value is shown in 24 hour format.
Temporary fix
Comments
APAR Information
APAR number
IC79952
Reported component name
WMQ EVERYPLACE
Reported component ID
5724C7700
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-23
Closed date
2012-04-16
Last modified date
2012-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ EVERYPLACE
Fixed component ID
5724C7700
Applicable component levels
R200 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.