Closed as program error.
Error description
When running 2 or more batch report jobs concurrently, the generated results are inconsistent. The generated result for a specific batch report job contains data points with timestamps outside the specified time range for the mentioned job, but within the time range of other batch jobs that were not running concurrently. This issue does not occur when the batch jobs are running separately. RECREATE STEPS: Run 2 or more batch report jobs concurrently.
Local fix
Run jobs separately.
Problem summary
**************************************************************** * USERS AFFECTED: Users of TPC 4.2.1 running batch reports * **************************************************************** * PROBLEM DESCRIPTION: When running 2 or more batch report * * jobs concurrently, the generated * * results are inconsistent. The * * generated result for a specific batch * * report job contains data points with * * timestamps outside the specified time * * range for the mentioned job, but * * within the time range of other batch * * jobs that were not running * * concurrently. This issue does not * * occur when the batch jobs * * are running separately. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | fix pack | 4.2.2-TIV-TPC-FP0002 - target April 2012 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC77791
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
42A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-07-29
Closed date
2011-09-14
Last modified date
2012-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R42A PSY
UP
R42H PSY
UP
R42L PSY
UP
R42S PSY
UP
R42W PSY
UP