Error description
New Option in HSM for Windows to control the Number of concurrent Recalls Problem Description: When an application is accessing a migrated file through a CIFS share, a system thread is started on the file server to send back the file content to the CIFS client. The system thread is blocked until the file is recalled by the HSM Recall service. Depending on the number of concurrent recalls and the time needed to recall each file, several system threads may be blocked at a time. However the number of system threads is limited and depends on the operating system configuration and hardware. The file server might become unresponsive with a high number of blocked system threads until some or all files are recalled and the system threads are unblocked. Affected Products: Tivoli Storage Manager HSM for Windows versions 5.4.x.x, 5.5.x.x and 6.1.0.0 to 6.1.4.0 (inclusive) Customer/L2 diagnostics (if applicable): No errors are reported by HSM for Windows, but file server is unresponsive for some period of time. Additional Keywords: HSM for Windows, system threads, freeze Initial Impact: File server is hanging
Local fix
Increase recall performance, e.g. by using more tape drives or using disk storage.
Problem summary
**************************************************************** * USERS AFFECTED: TSM HSM for Windows Client Versions * * 5.4.x.x, 5.5.x.x and 6.1.0.0 to 6.1.4.0 (inclusive) * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: Apply fixing level when available. This * * problem is currently projected to be fixed * * in fixtest 6.1.4.1. * * The new options are not available for * * versions 5.4 and 5.5. * ****************************************************************
Problem conclusion
The new option ConcurrentRecallLimit has been implemented to control the maximum number of concurrent recalls and with that also the number of blocked system threads and waiting applications. If a new recall request is initiated such that the number of concurrent recalls exceeds the value of ConcurrentRecallLimit, the HSM for Windows filter driver will not initiate the recall of the file, but immediately return the recall request with an error. The error code can be configured with the option ConcurrentRecallLimitCode. The value for ConcurrentRecallLimit applies to the total of all concurrent recalls regardless of whether they were triggered through CIFS access or local file system access. This option is different from the configurable amount of concurrent connections of the HSM recall service (see http://publib.boulder.ibm.com/infocenter/tsminfo/v6/topic/com. ibm.itsm.hsmwin.doc/c_recall_stngs.html) In order to activate the concurrent recall limit the administrator has to manually create one DWORD value in the Windows registry under HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\ithsmdrv \Parameters : Name: ConcurrentRecallLimit Type: REG_DWORD Value: Maximum number of allowed concurrent recalls. The minimum value is "1" and the maximum value is 0x7FFFFFFF. If the option is not set, the maximum value is used. Every concurrent recall request exceeding this number is immediately returned with an error. The error code returned is by default 0xC0000267 (STATUS_FILE_IS_OFFLINE). The system administrator can optionally change the error code by manually creating this DWORD value in the Windows registry at the same location: Name: ConcurrentRecallLimitCode Type: REG_DWORD Value: Error code returned to the application when ConcurrentRecallLimit is exceeded. If the option is not set, the default value of 0xC0000267 (STATUS_FILE_IS_OFFLINE) is returned. Consult with your Microsoft Windows system administrators or Microsoft Windows technical support before changing this value. After setting or changing any of these values the system must be rebooted in order to apply the changes. The return code received by the application is the only indication that the ConcurrentRecallLimit might have been exceeded. No errors are logged by HSM for Windows. Note file access errors can occur for any number of reasons. It is possible for applications to receive 0xC0000267 for reasons other than exceeding the ConcurrentRecallLimit. It is also possible for applications to receive other file access return codes unrelated to ConcurrentRecallLimit. The error message presented to the user depends on how the application handles the error code to an error message. These options should not be applied or changed without thorough testing. The behavior of the applications receiving errors cannot be predicted nor controlled by HSM for Windows. HSM for Windows is not responsible for any application or operating system malfunction as result of applying these options.
Temporary fix
Comments
APAR Information
APAR number
IC72637
Reported component name
TSM HSM FOR WIN
Reported component ID
5698ICNCL
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-19
Closed date
2010-11-19
Last modified date
2010-11-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ithsmdrv
Fix information
Fixed component name
TSM HSM FOR WIN
Fixed component ID
5698ICNCL
Applicable component levels
R610 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSATMW","label":"Tivoli Storage Manager HSM for Windows"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
19 November 2010