IBM Support

IC72637: NEW HSM FOR WINDOWS RECALL OPTION CONCURRENTRECALLLIMIT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • New Option in HSM for Windows to control the Number of
    concurrent Recalls
    
    Problem Description:
    When an application is accessing a migrated file through a CIFS
    share, a system thread is started on the file server to send
    back the file content to the CIFS client. The system thread is
    blocked until the file is recalled by the HSM Recall service.
    Depending on the number of concurrent recalls and the time
    needed to recall each file, several system threads may be
    blocked at a time. However the number of system threads is
    limited and depends on the operating system configuration and
    hardware. The file server might become unresponsive with a high
    number of blocked system threads until some or all files are
    recalled and the system threads are unblocked.
    
    Affected Products:
    Tivoli Storage Manager HSM for Windows versions 5.4.x.x, 5.5.x.x
    and 6.1.0.0 to 6.1.4.0 (inclusive)
    
    Customer/L2 diagnostics (if applicable):
    No errors are reported by HSM for Windows, but file server is
    unresponsive for some period of time.
    
    Additional Keywords: HSM for Windows, system threads, freeze
    
    
    Initial Impact: File server is hanging
    

Local fix

  • Increase recall performance, e.g. by using more tape drives or
    using disk storage.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: TSM HSM for Windows Client Versions          *
    * 5.4.x.x, 5.5.x.x and 6.1.0.0 to 6.1.4.0 (inclusive)          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION                                        *
    ****************************************************************
    * RECOMMENDATION: Apply fixing level when available. This      *
    *                 problem is currently projected to be fixed   *
    *                 in fixtest 6.1.4.1.                          *
    *                 The new options are not available for        *
    *                 versions 5.4 and 5.5.                        *
    ****************************************************************
    

Problem conclusion

  • The new option ConcurrentRecallLimit has been implemented to
    control the maximum number of concurrent recalls and with that
    also the number of blocked system threads and waiting
    applications. If a new recall request is initiated such that the
    number of concurrent recalls exceeds the value of
    ConcurrentRecallLimit, the HSM for Windows filter driver will
    not initiate the recall of the file, but immediately return the
    recall request with an error. The error code can be configured
    with the option ConcurrentRecallLimitCode.
    The value for ConcurrentRecallLimit applies to the total of all
    concurrent recalls regardless of whether they were triggered
    through CIFS access or local file system access.
    This option is different from the configurable amount of
    concurrent connections of the HSM recall service (see
    http://publib.boulder.ibm.com/infocenter/tsminfo/v6/topic/com.
    ibm.itsm.hsmwin.doc/c_recall_stngs.html)
    
    In order to activate the concurrent recall limit the
    administrator has to manually create one DWORD value in the
    Windows registry under
    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\ithsmdrv
    \Parameters :
    Name:  ConcurrentRecallLimit
    Type:  REG_DWORD
    Value: Maximum number of allowed concurrent recalls. The minimum
    value is "1" and the maximum value is 0x7FFFFFFF. If the option
    is not set, the maximum value is used. Every concurrent recall
    request exceeding this number is immediately returned with an
    error. The error code returned is by default 0xC0000267
    (STATUS_FILE_IS_OFFLINE).
    
    The system administrator can optionally change the error code by
    manually creating this DWORD value in the Windows registry at
    the same location:
    Name:  ConcurrentRecallLimitCode
    Type:  REG_DWORD
    Value: Error code returned to the application when
    ConcurrentRecallLimit is exceeded. If the option is not set, the
    default value of 0xC0000267 (STATUS_FILE_IS_OFFLINE) is
    returned. Consult with your Microsoft Windows system
    administrators or Microsoft Windows technical support before
    changing this value.
    
    After setting or changing any of these values the system must be
    rebooted in order to apply the changes.
    
    The return code received by the application is the only
    indication that the ConcurrentRecallLimit might have been
    exceeded. No errors are logged by HSM for Windows.
    
    Note file access errors can occur for any number of reasons. It
    is possible for applications to receive 0xC0000267 for reasons
    other than exceeding the ConcurrentRecallLimit. It is also
    possible for applications to receive other file access return
    codes unrelated to ConcurrentRecallLimit.
    The error message presented to the user depends on how the
    application handles the error code to an error message.
    
    These options should not be applied or changed without thorough
    testing. The behavior of the applications receiving errors
    cannot be predicted nor controlled by HSM for Windows.
    HSM for Windows is not responsible for any application or
    operating system malfunction as result of applying these
    options.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC72637

  • Reported component name

    TSM HSM FOR WIN

  • Reported component ID

    5698ICNCL

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-11-19

  • Closed date

    2010-11-19

  • Last modified date

    2010-11-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • ithsmdrv
    

Fix information

  • Fixed component name

    TSM HSM FOR WIN

  • Fixed component ID

    5698ICNCL

Applicable component levels

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSATMW","label":"Tivoli Storage Manager HSM for Windows"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date: