A fix is available
APAR status
Closed as program error.
Error description
Probes of DS8000 series Storage Subsystems fail, logging the following exception in the <specify log or location where error is seen>: HWNEP0134E Following exception occurred: com.ibm.tpc.ep.base.EPHdlrRunException:com.ibm.storage.ess.ni.ex ception.NIParameterInvalidServerException: completionStatus = 2, parameterClass = class [Lcom.ibm.storage.ess.ni.identifiers.NIVolumeID;, This problem is caused by an incompatibility between TPC 4.2 (specify if other versions are also affected) and the DS8K firmware version 2.4.x. This APAR resolves the functionality problem in TPC.
Local fix
Problem summary
Users Affected: TPC 4.2.x users with DS8000 storage systems running R2.4.x. Problem Description: See ERROR DESCRIPTION
Problem conclusion
A code change has been made to allow R2.4.x to work. The fix for this APAR is targeted for the following maintenance packages: | fix pack | 4.2.1-TIV-TPC-FP0001 - target December 2010 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC72442
Reported component name
TPC DEVICES-TPC
Reported component ID
TV0006BOS
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-09
Closed date
2010-11-10
Last modified date
2010-12-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MDM PERFORMANCE
Fixed component ID
5648GPC01
Applicable component levels
R420 PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSMMUP","label":"Tivoli Storage Productivity Center for Disk"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]