A fix is available
APAR status
Closed as program error.
Error description
when customer unplugs a fibre channel cable, the tpc topology display does not update to show the change or alert.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: TPC 4.1.x and 4.2.x users of Data Path * * Explorer where the Disks reside on a * * Windows server * **************************************************************** * PROBLEM DESCRIPTION: TPC is unable to generate all data * * paths for disks that reside on a * * Windows server when the data paths * * have been physically disconnected and * * reconnected from the fabric. * * * * A TPC Data agent successfully probed * * on a supported Windows system does * * not yield all the path information * * needed for the TPC Data Path Explorer * * (DPE) in the TPC Topology viewer after * * a fabric connection has been * * physically disconnected and * * reconnected. When attempting to * * generate the data paths, only some of * * the data paths are found. This * * occurs even when successfully probing * * the fabrics and subsystems that * * contain the connection information * * needed to relate the storage subsystem * * volumes to the Windows disks. This * * also occurs after a reboot of the * * Windows system following the * * connection of the host ports to the * * fabric. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
The data correlation has been corrected with a code change. The fix for this APAR is targeted for the following maintenance packages: | fix pack | 4.1.1-TIV-TPC-FP0006 - target April 2011 | fix pack | 4.2.1-TIV-TPC-FP0001 - target December 2010 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC70907
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
41W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-09-01
Closed date
2010-10-20
Last modified date
2010-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R41S PSY
UP
R41W PSY
UP
R42S PSY
UP
R42W PSY
UP