A fix is available
APAR status
Closed as program error.
Error description
TPC shows wrong status of Brocade SAN Switch In Topology -> Switches, TPC shows some type of SAN Switches in Status "Warning". This happens on Brocade SAN Switches when Ports are enable but not connected.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: TPC 3.3.2, 4.1.0 and 4.1.1 users * * monitoring Brocade * **************************************************************** * PROBLEM DESCRIPTION: Unlicensed Brocade FC Ports are shown * * with warning in TPC Topology, thus * * making the switches to which they * * belong to be in warning also(assuming * * this is the only warning reason there * * is). Unlicensed ports should not * * cause a warning that may mask other * * conditions creating a valid warning * * state. * **************************************************************** * RECOMMENDATION: * **************************************************************** According to SMIS 1.5 specification the Consolidate Status should be Ok ,resulting from OperationalStatus=Stopped and EnabledState=Diabled
Problem conclusion
The unlicensed ports will be displayed according to the SMI-S 1.5 specification, which will allow them to report as Ok and not a warning state. The fix for this APAR is targeted for the following maintenance packages: | fix pack | 4.1.1-TIV-TPC-FP0005 - target October 2010 | fix pack | 3.3.2-TIV-TPC-FP0010 - target to be determined http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC69303
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
41A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-06-17
Closed date
2010-08-10
Last modified date
2010-08-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R33A PSY
UP
R33L PSY
UP
R33W PSY
UP
R41A PSY
UP
R41L PSY
UP
R41W PSY
UP