A fix is available
APAR status
Closed as program error.
Error description
TPC dbschema upgrade fails with error INS5007E: Installation failed (log: '{0}'). Root cause is that the environmental variable %TEMP% is set with spaces embedded in it resulting in the file tpcdbcfg.out being written to a different location. This will result in the installer not being able to locate the file which is needed in order continue with the upgrade. Need to address the issue by either changing the installer code so that it can handle %TEMP% with spaces or improve debugging to show FileNotFound Exception in dbschemainstall.log, so that customer can edit %TEMP% to a path devoid of spaces. RECREATE STEPS: Perform a TPC upgrade with spaces embedded in variable %TEMP%.
Local fix
Set %TEMP% with no spaces. Example, change %TEMP% to C:\temp.
Problem summary
**************************************************************** * USERS AFFECTED: Those installing TPC 4.1.0 and 4.1.1 * **************************************************************** * PROBLEM DESCRIPTION: See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
A fix has been made to better handle spacew within the path for %TEMP%. It is targeted for the following maintenance package: | fix pack | 4.1.1-TIV-TPC-FP0005 - target October 2010 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Set %TEMP% with no spaces.
Comments
APAR Information
APAR number
IC69246
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
41W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-06-15
Closed date
2010-08-10
Last modified date
2010-08-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R41A PSY
UP
R41L PSY
UP
R41W PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB5","label":"Tivoli Storage Productivity Center for Data"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"41W"}]
Document Information
Modified date:
17 September 2021