IBM Support

IC68190: TPC CIMOM DISCOVERY SHOW HWN021531E FOR EMC CLARIION DEVICES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • TPC CIMOM Discovery show HWN021531E for EMC Clariion devices and
    is not anymore able to redetect these Clariion. The further
    issues are that the systems can be shown as unreachable even if
    they are up and running.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: TPC 4.1.1.FP2 (4.1.1.74) environments using  *
    *                 EMC CIMOMs to get data about EMC Clariion    *
    *                 storage devices.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: TPC CIMOM Discovery is reporting job    *
    *                      state as successful,but message log     *
    *                      provided error HWN021531E for           *
    *                      Clariion devices.  The storage device   *
    *                      is not anymore detected and was set     *
    *                      to "unreachable". This should never     *
    *                      happen for Clariion, only for wrongly   *
    *                      configured Symmetrix.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    -
    

Problem conclusion

  • A code change was made to TPC 4.1.1.FP3 which solve this
    issue.  The fix for this APAR is targeted for the following
    maintenance package:
    
        | fix pack | 4.1.1-TIV-TPC-FP0003 - target May 2010
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future fix packs do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    
    Alternative Action: Immediately contact IBM support to
    get a Hotfix for this.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC68190

  • Reported component name

    TPC FOR DATA

  • Reported component ID

    5608TC300

  • Reported release

    41A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-04-28

  • Closed date

    2010-04-29

  • Last modified date

    2010-04-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC FOR DATA

  • Fixed component ID

    5608TC300

Applicable component levels

  • R41A PSY

       UP

  • R41H PSY

       UP

  • R41L PSY

       UP

  • R41N PSY

       UP

  • R41S PSY

       UP

  • R41W PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB5","label":"Tivoli Storage Productivity Center for Data"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"41A"}]

Document Information

Modified date:
16 September 2021