A fix is available
APAR status
Closed as program error.
Error description
DETAIL OF PROBLEM: TPC Data/Fabric agents installed on SAN-attached filesystems on HPUX 11.11 servers fail to start at system boot due to the agent start script being called before the SAN-attached drives re-attach to the server. When the startup process is initiated on HPUX and the /sbin/rc script is invoked, a list of scripts is created containing all the scripts that are going to be executed during boot sequence, from all the involved run levels. Scripts are only added to this list if the scripts referenced by symbolic links actually physically exist on the system. Since the Common Agent statup script is not available at that point due to the SAN disk not being mounted yet, the script does not get included in the list, and thus the Common Agent does not start during bootup. A code change is being made that modifies the data agent/fabric agent installers to dynamically generate the startup script and modify the rc.X links. The script is a wrapper which calls the common agent startup script and will be put in the HPUX server's /etc/init.d file; the way its currently written, it cannot put itself in /etc/init.d during install. RECREATE STEPS: Install A TPC Data and/or Fabric agent on SAN-attached disk on an HPUX server then reboot. The common agent process will not be launched. ________________________________________________________________ DB2 Version used for Server: N/A The defect is against component: 5608TC300 Server/Manager build/release (TPC): 4.1.1.66 Agent build/release (TPC): 4.1.1.66 Server/Manager (OS): N/A Agent (OS): HPUX 11.11 ________________________________________________________________ Problem as described by customer: HPUX agents do not start automatically at boot time. Initial customer impact (low/med/high): med
Local fix
None known.
Problem summary
**************************************************************** * USERS AFFECTED: TPC 3.3.2, 4.1.0 and 4.1.1 users who install * * TPC Data or Fabric Agents on HP-UX OS, * * on SAN attached disks. * **************************************************************** * PROBLEM DESCRIPTION: If TPC Data Agent or Fabric Agent * * are installed on SAN attached disks * * on HP-UX OS then they might not get * * started when the system is rebooted. * **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
Create a script in /sbin/init.d/ to start the Common Agent. Regenerate following links to point to this script: /sbin/rc0.d/K71itca0 /sbin/rc3.d/S71itca0 /sbin/rc4.d/S71itca0 The fix for this APAR is targeted for the following maintenance packages: | fix pack | 4.1.1-TIV-TPC - FP0005 - target October 2010 | fix pack | 3.3.2-TIV-TPC - FP0010 - target not yet set http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC68127
Reported component name
TPC FOR DATA
Reported component ID
5608TC300
Reported release
41H
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-22
Closed date
2010-06-22
Last modified date
2010-07-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR DATA
Fixed component ID
5608TC300
Applicable component levels
R33H PSY
UP
R41H PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB5","label":"Tivoli Storage Productivity Center for Data"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"41H"}]
Document Information
Modified date: