IBM Support

IC61009: ANR0102E MESSAGE WHEN A SELECT STATEMENT IS RUN AGAINST THE ADMINS TABLE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An ANR0102E error 8 inserting row in table adminst message is
    issued when a select statement is run against the admins table.
    This can be caused by issuing the command manually or if it is
    entered by another process.  An example of this would be when
    adding a server connection in the Administration Center.  It is
    possible for the length of the data being inserted into a column
    in the table to be longer thanthe defined length for that
    column.
    
    TSM Versions Affected: TSM 6.1 servers on all platforms
    
      Customer/L2 Diagnostics: A trace with  flags DB, DBEXEC, and
    ADM will show the value that is being entered into the adminst.
    For example:
    
    [tbcli.c][9778][TraceSetInputParameters]:col=8,
    name=STORAGE_PRIV, type=STRING, value=XXXXXX
    
    If the length of this value is greater than the length of field
    in the table, the error will occur
    
    Initial Impact: Low
      Additional Keywords: ANR0162W, ANR0157W, ANR0158W, Admin
    Center, AC, add server connection, ADMIN_CENTER, admins,
    adminst, zz61
    

Local fix

  • It may be possible to reduce the length of the data being
    inserted into the temporary table by reducing the length of some
    of the attributes of the failing adminstrator.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Tivoli Storage Manager 6.1 Windows and   *
    *                 UNIX servers using the Administrative        *
    *                 Client.                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: See error description                   *
    ****************************************************************
    * RECOMMENDATION: Apply fixing level when available. This      *
    *                 problem is currently projected to be fixed   *
    *                 in level 6.1.2. Note that this is            *
    *                 subject to change at the discretion of IBM   *
    ****************************************************************
    *
    

Problem conclusion

  • This problem was fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC61009

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    55W

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-05-05

  • Closed date

    2009-06-05

  • Last modified date

    2009-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R61A PSY

       UP

  • R61H PSY

       UP

  • R61L PSY

       UP

  • R61S PSY

       UP

  • R61W PSY

       UP

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"55W"}]

Document Information

Modified date:
15 September 2021