Fixes are available
APAR status
Closed as program error.
Error description
When an image backup is performed with a 5.5.0.6 or lower TSM UNIX client, that image backup cannot be restored with a V6.1 TSM UNIX client. The following error message is issued: ANS1166E Source and destination are not the same file system type and the 'RESTORE IMAGE' command fails. This problem can also be seen with the 5.5.1.11+ UNIX interim fix and Limited Availability interim fix clients built on top of 5.5.1.10 The V6.1 Windows client is unaffected and is able to restore image backups.
Local fix
Continue using the V5.5.1.10 or lower TSM UNIX/Linux backup clients to restore image backups.
Problem summary
**************************************************************** * USERS AFFECTED: Version 5.5.1.11 and higher 5.5.1.x, and * * version 6.1.0 backup-archive clients on all * * Unix and NetWare platforms * **************************************************************** * PROBLEM DESCRIPTION: See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: Apply fixing level when available. This * * problem is currently projected to be fixed * * in levels 5.5.2 and 6.1.1. Note that this * * is subject to change at the discretion of * * IBM. * **************************************************************** *
Problem conclusion
The problem described in this APAR has been fixed so that it no longer occurs.
Temporary fix
Comments
APAR Information
APAR number
IC60513
Reported component name
TSM CLIENT
Reported component ID
5698ISMCL
Reported release
61A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-23
Closed date
2009-03-30
Last modified date
2009-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DSMC
Fix information
Fixed component name
TSM CLIENT
Fixed component ID
5698ISMCL
Applicable component levels
R54A PSY
UP
R54E PSY
UP
R54H PSY
UP
R54I PSY
UP
R54L PSY
UP
R54M PSY
UP
R54N PSY
UP
R54P PSY
UP
R54S PSY
UP
R54X PSY
UP
R55A PSY
UP
R55E PSY
UP
R55H PSY
UP
R55I PSY
UP
R55L PSY
UP
R55M PSY
UP
R55N PSY
UP
R55P PSY
UP
R55S PSY
UP
R55T PSY
UP
R55Z PSY
UP
R61A PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.