A fix is available
APAR status
Closed as program error.
Error description
Websphere Host-OnDemand ----------------------- The VT session is missing information on the screen. Apparently, the information comes from the HOST in two frames and HOD clears the first set of information before displaying the second frame of information. Hod should not be erasing the data, and this is why the information is missing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Normal VT Terminal Users * * * **************************************************************** * PROBLEM DESCRIPTION: When clients are using VT display * * session, some data is missing on the * * screen. * **************************************************************** * RECOMMENDATION: * **************************************************************** When Host On-Demands was incorrectly parsed the "Copy Rectangular Area (DECCRA)". The problem is caused by the minimum row and minimum column values for Pbs and Prs are set to zero "0" or if the values are not set at all. As a result, this resulted in the copy of a single character instead of the whole page. As a result, data is missing on the display screen.
Problem conclusion
The code was modified to properly set the values for Pbs and Prs.
Temporary fix
Comments
APAR Information
APAR number
IC52769
Reported component name
HOD
Reported component ID
5733A5901
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-05-22
Closed date
2007-05-28
Last modified date
2007-09-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CSISEQUE
Fix information
Fixed component name
HOD
Fixed component ID
5733A5901
Applicable component levels
R900 PSY IP22933
UP07/09/14 I 1000
RA00 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSS9FA","label":"IBM Host On-Demand"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]