IC52234: HOD: IF DBCS STRINGS IS PASTED INTO THE AREA WHERE UNPROTECTED FIELD IS INCLUDED,IT IS NOT PASTED CORRECTLY.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the DBCS strings is pasted into the area where unprotected
    field is included,it is not pasted correctly.
    .
    Example:
     If DBCS character 'ABCDEF' is copied and those those strings
    are pasted on the following field,the result is below.
    .
               1 2 3 4 5 6
      field -> P P P U U U
      copy  -> A B C D E F
      paste ->       A D E
    .
     Expected results are below.
    .
               1 2 3 4 5 6
      field -> P P P U U U
      copy  -> A B C D E F
      paste ->       D E F
    .
    Note:
      Field line - P : DBCS protection field
                 - U : DBCS unprotected field
      Copy line      : ABCDEF is DBCS character
    

Local fix

Problem summary

  • ****************************************************************
    *USERS AFFECTED: HOD JPN 3270 DISPLAY SESSION USERS
    ****************************************************************
    *PROBLEM DESCRIPTION: Copy and paste incorrect with full screen
    ****************************************************************
    *RECOMMENDATION:
    ****************************************************************
    *Reached HOD version and platform
    HOD9.0.6
    *Bad case
    When pasting data to proptected field, HOD does not handle the
    data length well for DBCS data.
    

Problem conclusion

  • Correct the logic of handling DBCS data length when paste data
    to protected field.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC52234

  • Reported component name

    HOD

  • Reported component ID

    5733A5901

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-03-26

  • Closed date

    2007-03-27

  • Last modified date

    2007-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    PS3270
    

Fix information

  • Fixed component name

    HOD

  • Fixed component ID

    5733A5901

Applicable component levels

  • R900 PSN IP22933

       UP07/09/14 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSS9FA","label":"IBM Host On-Demand"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
19 April 2021