IBM Support

HE01148: WHEN GEOMETRICAL TOLERANCE IS SELECTED BY OBJECT RESOLUTION, IT IS SELECTED BY THE UNIT OF VIEW.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Scenario:
    1. Open the specific CATDrawing file in CATIA.
    2. Go to Tools>Macro>Visual Basic Editor.
    3. In the VB Editor, click on Insert>Object Resolution.
    4. When the drawing is shown, move pointer over the text and
    then the tolerances and observe.
    Problem:
     When the pointer is moved over the text/text with
    leader/balloon, only those attributes get selected.
    When the tolerance symbols are chosen, then all the
    attributes in the drawing are selected including the text.
    Expected Result:
     When pointer is moved over tolerance symbols, only tolerance
    symbols should get activated.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open the specific CATDrawing file in CATIA.
    2. Go to Tools>Macro>Visual Basic Editor.
    3. In the VB Editor, click on Insert>Object Resolution.
    4. When the drawing is shown, move pointer over the text and
    then the tolerances and observe.
    Problem:
     When the pointer is moved over the text/text with
    leader/balloon, only those attributes get selected.
    When the tolerance symbols are chosen, then all the
    attributes in the drawing are selected including the text.
    Expected Result:
     When pointer is moved over tolerance symbols, only tolerance
    symbols should get activated.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    Incident Diagnosis:
    Object resolution does not work correctly with geometric
    tolerances
    Reason:
    Object Resolution is based on the automation model objects
    exposition. If an object such as
    Geometric tolerance is selected, this tool can not run
    successfully because geometric
    tolerance is not exposed in automation
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE01148

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-10-21

  • Closed date

    2010-10-22

  • Last modified date

    2010-10-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
22 October 2010