Error description
- SCENARIO --------------- 1. Install CATIA 2. Install ENOVIA V5 VPM into the same installation directory (of step 1) (to be able to use the ENOVIA V5 VPM Navigator toolbar within the CATIA session) 3. Install the CATIA documentation into a directory and the ENOVIA V5 VPM documentation into a different directory. Remark: It is not possible to install the ENOVIA V5 VPM documentation into an installed CATIA documentation, and vice versa. Error message in this case: <Installation directory> must be empty 4. Start a CATIA session with the generated CATIA environment file (of step 1), e.g. (in one line): <Code_inst_dir>\intel_a\code\bin\CATSTART.exe -env CATIA_P3.V5R20.B20 -direnv <CATEnv_dir> -run "CNEXT" 5. In the CATIA session declare both documentation directories of step 3 in TOOLS / OPTIONS / GENERAL / HELP / TECHNICAL DOCUMENTATION / LOCATION and then confirm this with button OK. 6. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> Only the CATIA V5 documentation appears in the web browser (ERROR) Expected result: The customer expects to be able to read and search both the CATIA and the ENOVIA V5 VPM documentation 7. In the CATIA session remove the CATIA documentation from the declaration (see step 5), leaving only the ENOVIA V5 VPM documentation declared. 8. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> No documentation appears (ERROR), only the error message: No document is associated to the current command Expected result: The declared ENOVIA V5 VPM documentation should appear. 9. Exit the running CATIA session 10. Start a new CATIA session with the generated ENOVIA V5 VPM environment file (of step 2), e.g. (in one line): <Code_inst_dir>\intel_a\code\bin\CATSTART.exe -env ENOVIA_V5_VPM.V5R20.B20 -direnv <CATEnv_dir> -run "CNEXT" 11. In the CATIA session declare both documentation directories of step 3 in TOOLS / OPTIONS / GENERAL / HELP / TECHNICAL DOCUMENTATION / LOCATION and then confirm this with button OK. 12. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> Only the ENOVIA V5 VPM documentation appears in the web browser (ERROR) And the ENOVIA V5 VPM documentation appears without header and without left navigation bar (ERROR) See the screenshot "Negative_result_for_V5_VPM_docu_with_V5_VPM_env_file.JPG" Expected result: The customer expects to be able to read and search both the CATIA and the ENOVIA V5 VPM documentation And the header and the left navigation bar should appear for the ENOVIA V5 VPM documentation 13. In the CATIA session remove the ENOVIA V5 VPM documentation from the declaration (see step 11), leaving only the CATIA documentation declared. 14. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> No documentation appears (ERROR), only the error message: No document is associated to the current command Expected result: The declared CATIA documentation should appear. - Result : Problem reproduced both on customer's reported level, as well as on currently latest available level.
Local fix
empty
Problem summary
- SCENARIO --------------- 1. Install CATIA 2. Install ENOVIA V5 VPM into the same installation directory (of step 1) (to be able to use the ENOVIA V5 VPM Navigator toolbar within the CATIA session) 3. Install the CATIA documentation into a directory and the ENOVIA V5 VPM documentation into a different directory. Remark: It is not possible to install the ENOVIA V5 VPM documentation into an installed CATIA documentation, and vice versa. Error message in this case: <Installation directory> must be empty 4. Start a CATIA session with the generated CATIA environment file (of step 1), e.g. (in one line): <Code_inst_dir>\intel_a\code\bin\CATSTART.exe -env CATIA_P3.V5R20.B20 -direnv <CATEnv_dir> -run "CNEXT" 5. In the CATIA session declare both documentation directories of step 3 in TOOLS / OPTIONS / GENERAL / HELP / TECHNICAL DOCUMENTATION / LOCATION and then confirm this with button OK. 6. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> Only the CATIA V5 documentation appears in the web browser (ERROR) Expected result: The customer expects to be able to read and search both the CATIA and the ENOVIA V5 VPM documentation 7. In the CATIA session remove the CATIA documentation from the declaration (see step 5), leaving only the ENOVIA V5 VPM documentation declared. 8. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> No documentation appears (ERROR), only the error message: No document is associated to the current command Expected result: The declared ENOVIA V5 VPM documentation should appear. 9. Exit the running CATIA session 10. Start a new CATIA session with the generated ENOVIA V5 VPM environment file (of step 2), e.g. (in one line): <Code_inst_dir>\intel_a\code\bin\CATSTART.exe -env ENOVIA_V5_VPM.V5R20.B20 -direnv <CATEnv_dir> -run "CNEXT" 11. In the CATIA session declare both documentation directories of step 3 in TOOLS / OPTIONS / GENERAL / HELP / TECHNICAL DOCUMENTATION / LOCATION and then confirm this with button OK. 12. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> Only the ENOVIA V5 VPM documentation appears in the web browser (ERROR) And the ENOVIA V5 VPM documentation appears without header and without left navigation bar (ERROR) See the screenshot "Negative_result_for_V5_VPM_docu_with_V5_VPM_env_file.JPG" Expected result: The customer expects to be able to read and search both the CATIA and the ENOVIA V5 VPM documentation And the header and the left navigation bar should appear for the ENOVIA V5 VPM documentation 13. In the CATIA session remove the ENOVIA V5 VPM documentation from the declaration (see step 11), leaving only the CATIA documentation declared. 14. In the CATIA session press key F1 or menu HELP / CATIA V5 help ==> No documentation appears (ERROR), only the error message: No document is associated to the current command Expected result: The declared CATIA documentation should appear. - Result : Problem reproduced both on customer's reported level, as well as on currently latest available level.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION. Additional Closure Information: Incident Diagnosis: Only one documentation media is available at the same time. Reason: There is no common file between two different documentation media. CATIA documentation frame files (top and left parts), mapping tables and topic files are different from ENOVIA V5 VPM documentation frame, mapping tables (except for the CommonId2url.CATNls mapping table which contains links to topics available in only one documentation media) and topic files. When you start CATIA application, you are in a specific environment (CATIA OR ENOVIA V5 VPM in your case), and this environment defines which documentation frame files (online\CATIAAfr_C2\... OR online\lcafr_L2\...) and mapping tables (resources\msgcatalog\CATIA_P3Id2url.CATNls OR resources\msgcatalog\ENOVIA_V5_VPMId2url.CATNls) will be accessed from the root defined in Tools>Options to build the HTML page associated with the current command. By-Pass: It is possible to access topic files from both CATIA_P3 and ENOVIA_V5_VPM documentation media by copying CATIA_P3Id2url.CATNls and ENOVIA_V5_VPMId2url.CATNls in CommonId2url.CATNls. However, for topics available in both documentation media, only the first topic file found in the common mapping table will be found (however most of time the content of topic files should be the same so it's not a big problem). Another point is that for topics that are not in the documentation media defined in the environment file, the frame files will not be found and then will remain blank (as in your tests).
Temporary fix
Comments
APAR Information
APAR number
HD95246
Reported component name
ENOVIA V5 VPM N
Reported component ID
569151400
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-08
Closed date
2010-06-25
Last modified date
2010-06-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
25 June 2010