APAR status
Closed as Permanent restriction.
Error description
SCENARIO: 1. Start CATIA V5 2. Open the CATPart 3. Update the CATPart Observation: Warning message appears. Solid.340: Copy paste operation is impossible due to selection problems in master part or in master feature. The feature naming is incomplete. Recreate the master feature Edge fillet.786: The system implements a solution for computing the fillet. Check if the result obtained is satisfactory. 4. Right click on DZG_Einschussdusen_vorhalt and select copy 5. Right click on WMK_UT, select paste special / As result with link Observation: Error message appears as "Solid.340: Copy Paste operation is impossible due to selection problems in master part or in master feature. The feature naming is incomplete. Recreate the master feature. . PROBLEM: Impossible to paste a specific body and error message is displayed.
Local fix
Problem summary
SCENARIO: 1. Start CATIA V5 2. Open the CATPart 3. Update the CATPart Observation: Warning message appears. Solid.340: Copy paste operation is impossible due to selection problems in master part or in master feature. The feature naming is incomplete. Recreate the master feature Edge fillet.786: The system implements a solution for computing the fillet. Check if the result obtained is satisfactory. 4. Right click on DZG_Einschussd sen_vorhalt and select copy 5. Right click on WMK_UT, select paste special / As result with link Observation: Error message appears as "Solid.340: Copy Paste operation is impossible due to selection problems in master part or in master feature. The feature naming is incomplete. Recreate the master feature. . PROBLEM: Impossible to paste a specific body and error message is display . PROBLEM: Impossible to paste a specific body and error message is displayed.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Additional Closure Information: . Incident Diagonsis: The error displayed after paste operation is due to the generic naming KO. Two or more cells/faces have same naming which is wrong and should not happen . The problem comes from Draft.75 which creates this generic naming KO . Restriction Explanation: However, it is not the Draft feature which has BUG but the input geometry to the Draft feature is not stable Split.32, input to Draft.75, is created from surface Teilung_WMU . User should use check functionality on Join function to identify the problem before using such Join geometry for sunsequesnt
Temporary fix
Comments
APAR Information
APAR number
HD90107
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-10-27
Closed date
2009-10-27
Last modified date
2009-10-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
27 October 2009