  • Closed as Permanent restriction.

Error description

  • SCENARIO:
    Operation:
    1.Open the attached CATAnalysis file.
    2.Change workbench to the Generative Structural Analysis W/B.
    3.Double click on the Spot Welding Connection Property in the
    Properties.1.
    4.Select the Beam as the Type.
    5.Click the Component edition button.
    6.Select the Cylindrical beam as the type.
    7.Click the Component edition button.
    8.Input the 1mm as the Radius.
    9.Click the OK button.
    10.Select the Point.1 in the SUR_B.CATPart as the Orientation
    geometry.
    11.Click the OK button.
    12.Click the OK button.
    13.Select the Clamp command.
    14.Select the edge of the SUR_B as shown in the attached
    image.
    15.Click the OK button.
    16.Select the Force Density command.
    17.Select the SUR_A.CATPart as the Support.
    18.Input the -1000N as the Z of the Force Vector.
    19.Click the OK button.
    20.Select the Compute All command.
    RESULT:
    An error occurs and the Compute is interrupted
    ADDITIONAL INFO:
    - This trouble also occurs when the Spring-Rigid-Spring or the
    Rigid-Spring-Rigid is selected as Step4
    - This trouble does NOT occur when the Non-Compatible is
    selected as the Mesh Compatibility.
    .
    EXPECTED RESULT:
    The Compute should be performed when the Compatible is setup.
    .
    

Local fix

Problem summary

  • SCENARIO:
    Operation:
    1.Open the attached CATAnalysis file.
    2.Change workbench to the Generative Structural Analysis W/B.
    3.Double click on the Spot Welding Connection Property in the
    Properties.1.
    4.Select the Beam as the Type.
    5.Click the Component edition button.
    6.Select the Cylindrical beam as the type.
    7.Click the Component edition button.
    8.Input the 1mm as the Radius.
    9.Click the OK button.
    10.Select the Point.1 in the SUR_B.CATPart as the Orientation
    geometry.
    11.Click the OK button.
    12.Click the OK button.
    13.Select the Clamp command.
    14.Select the edge of the SUR_B as shown in the attached
    image.
    15.Click the OK button.
    16.Select the Force Density command.
    17.Select the SUR_A.CATPart as the Support.
    18.Input the -1000N as the Z of the Force Vector.
    19.Click the OK button.
    20.Select the Compute All command.
    RESULT:
    An error occurs and the Compute is interrupted
    ADDITIONAL INFO:
    - This trouble also occurs when the Spring-Rigid-Spring or the
    Rigid-Spring-Rigid is selected as Step4
    - This trouble does NOT occur when the Non-Compatible is
    selected as the Mesh Compatibility.
    .
    EXPECTED RESULT:
    The Compute should be performed when the Compatible is setup.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA.
    Additional Closure Information:
    INCIDENT DIAGNOSIS:
    If Compatible mesh is used for spot weld connection,
    singularity error is shown.
    RESTRICTION EXPLANATION:
    - If Beam type of connection is used for weld with compatible
    mesh, the beam introduces stiffness in rotational direction.
    - Due to this beam stiffness in rotational direction, local
    rotational singularity is not detected.
    - However, the beam is still free to rotate about its axis.
    This is a global singularity and hence the singularity error
    is shown and model is not computed.
    - With non-compatible mesh, additional nodes are generated by
    orthogonal projection. There nodes have kinematic relations
    with their surrounding nodes.
    - Due to kinematic relations, there is no rotational
    singularity and model is computed.
    Due to this reason the current behavior can not be changed.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD88016

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-18

  • Closed date

    2009-08-28

  • Last modified date

    2009-08-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
28 August 2009