APAR status
Closed as program error.
Error description
PROBLEM: Macro is not executed . SCENARIO: 01. Start CATIA 02. Tools / Macro / Macros 03. SupportLines.catvba and VBAProject1.catvba are added to the library (Or you can create your own CATVB file using the attached text file which has the macro code) 04. File/New(Part) 05. Tools / Macro / Macros 06. TEST_3D is chosen and Run . RESULT: Macro is not executed . EXPECTED RESULT: Macro should be executed and should create a Fill as shown in the image shown in presentation file . .
Local fix
Problem summary
PROBLEM: Macro is not executed . SCENARIO: 01. Start CATIA 02. Tools / Macro / Macros 03. SupportLines.catvba and VBAProject1.catvba are added to the library (Or you can create your own CATVB file using the attached text file which has the macro code) 04. File/New(Part) 05. Tools / Macro / Macros 06. TEST_3D is chosen and Run . RESULT: Macro is not executed . EXPECTED RESULT: Macro should be executed and should create a Fill as shown in the image shown in presentation file .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R20 GA level. Additional Closure Information: NOTE: For V5R19 Documentation for this issue will be delievered in the Program Directory of V5R19 SP07. This documentation explains user need to upgrade the VBA version to 6.5 to overcome this issue. In the program Directory this explaination can be found at: Manual Reference: Prerequisites > Solutions and Products > General and Open Issues > CATIA Infrastructure > CATIA Object Manager Topic: General Issues Documentation after correction is as below: VBA When using VBA in a 64-bit environment, you may encounter an error message from VBA indicating memory allocation problems or may not even succeed in loading your VBA project. These problems can be removed by upgrading to the most recent version, VBA 6.5. The VBAIDEinst.exe executable allows you to install the latest version of VBA. To perform this upgrade: Select Start > Programs > Command Prompt to open a Command Prompt window. Go to the directory of the installation CD 1, then to the Intel or win64 folder. Enter the command: VBAIDEinst.exe
Temporary fix
Comments
APAR Information
APAR number
HD85675
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-06-12
Closed date
2009-11-20
Last modified date
2009-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: