HD73017: ASD: SCENE FOR ONE PRODUCT IS LOST WHEN IT IS OPENED
APAR status
Closed as program error.
Error description
-
ABSTRACT: ASD: SCENE FOR ONE PRODUCT IS LOST WHEN IT IS OPENED WITH ANOTHER PRODUCT. . SCENARIO: 1. Launch CATIA V5R18SP3 & go to Assembly Design w/b. 2. Open Product1.CATProduct. 3. As you can see it contain a scene and everything is ok. 4. Close Catia. 5. Open a new Catia session. 6. Open "TEST.CATProduct". 7. As you can see it contain two scenes and everything is ok. 8. Open Product1.CATProduct in the same Catia session. 9. Link to CATNewScenesStup.CATfct is lost and the scene do not appear in the Catia tree. . RESULT: The scene for one product is lost when it is opened with another product. . EXPECTED RESULT: The scene for one product should not be lost when it is opened with another product. .
Local fix
Problem summary
-
ASD: SCENE FOR ONE PRODUCT IS LOST WHEN IT IS OPENED WITH ANOTHER PRODUCT ABSTRACT: ASD: SCENE FOR ONE PRODUCT IS LOST WHEN IT IS OPENED WITH ANOTHER PRODUCT. . SCENARIO: 1. Launch CATIA V5R18SP3 & go to Assembly Design w/b. 2. Open Product1.CATProduct. 3. As you can see it contain a scene and everything is ok. 4. Close Catia. 5. Open a new Catia session. 6. Open "TEST.CATProduct". 7. As you can see it contain two scenes and everything is ok. 8. Open Product1.CATProduct in the same Catia session. 9. Link to CATNewScenesStup.CATfct is lost and the scene do not appear in the Catia tree. . RESULT: The scene for one product is lost when it is opened with another product. . EXPECTED RESULT: The scene for one product should not be lost when it is opened with another product. .
Problem conclusion
-
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP01 AND ON V5R18SP07. Incident Diagnosis ASD: SCENE FOR ONE PRODUCT IS LOST WHEN IT IS OPENED WITH ANOTHER PRODUCT. Correction Explanation The new scenes are not retreived because the CATProduct has links to the CATNewScenesStUp feature catalog in uppercase. We are not able to reproduce such a CATProduct. As a consequence, we can just clean the corrupted CATProduct. .
Temporary fix
Comments
APAR Information
APAR number
HD73017
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-04-02
Closed date
2008-09-23
Last modified date
2008-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R518 PSN SP51807
UP08/10/29 I 1000