IBM Support

Security Bulletin: Vulnerability in SSLv3 and OpenSSL affect SAN Volume Controller and Storwize Family (CVE-2014-3566 CVE-2014-3567)

Security Bulletin


Summary

There are security vulnerabilities in SSLv3 that is used by SAN Volume Controller and Storwize Family. In addition, OpenSSL vulnerabilities along with SSL 3 Fallback protection (TLS_FALLBACK_SCSV) were disclosed on October 15, 2014 by the OpenSSL Project. OpenSSL is used by SAN Volume Controller and Storwize Family. SAN Volume Controller and Storwize Family has addressed the applicable CVEs and included the SSL 3.0 Fallback protection (TLS_FALLBACK_SCSV) provided by OpenSSL.

Vulnerability Details

CVE-ID: CVE-2014-3566

DESCRIPTION: Product could allow a remote attacker to obtain sensitive information, caused by a design error when using the SSLv3 protocol. A remote user with the ability to conduct a man-in-the-middle attack could exploit this vulnerability via a POODLE (Padding Oracle On Downgraded Legacy Encryption) attack to decrypt SSL sessions and access the plaintext of encrypted connections.

CVSS Base Score: 4.3
CVSS Temporal Score: See http://xforce.iss.net/xforce/xfdb/97013 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (AV:N/AC:M/Au:N/C:P/I:N/A:N)

CVE-ID: CVE-2014-3567
DESCRIPTION: OpenSSL is vulnerable to a denial of service, caused by a memory leak when handling failed session ticket integrity checks. By sending an overly large number of invalid session tickets, an attacker could exploit this vulnerability to exhaust all available memory of an SSL/TLS or DTLS server.
CVSS Base Score: 5.0
CVSS Temporal Score: See http://xforce.iss.net/xforce/xfdb/97036 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (AV:N/AC:L/Au:N/C:N/I:N/A:P)

Affected Products and Versions

IBM SAN Volume Controller
IBM Storwize V7000
IBM Storwize V5000
IBM Storwize V3700
IBM Storwize V3500
IBM Flex System V7000

All products are affected when running any releases, from 1.1 to 7.3.

Remediation/Fixes

IBM recommends that you fix this vulnerability by upgrading affected versions of IBM SAN Volume Controller, IBM Storwize V7000, V5000, V3700 and V3500 to the following code levels or higher:

7.1.0.12
7.2.0.10
7.3.0.8

Latest SAN Volume Controller Code
Latest Storwize V7000 Code
Latest Storwize V5000 Code
Latest Storwize V3700 Code
Latest Storwize V3500 Code

IBM recommends that you fix this vulnerability by upgrading affected versions of IBM Flex System V7000 to the following code levels or higher:

7.2.0.10

Latest IBM Flex System V7000 Code

IBM recommends that you review your entire environment to identify areas that enable the SSLv3 protocol and take appropriate mitigation and remediation actions. The most immediate mitigation action that can be taken is disabling SSLv3. You should verify disabling SSLv3 does not cause any compatibility issues.

Workarounds and Mitigations

None known

Get Notified about Future Security Bulletins

Get Notified about Future Security Bulletins

References

Off

Acknowledgement

None

Change History

21 Nov 2014: Published draft

*The CVSS Environment Score is customer environment specific and will ultimately impact the Overall CVSS Score. Customers can evaluate the impact of this vulnerability in their environments by accessing the links in the Reference section of this Security Bulletin.

Disclaimer

Review the IBM security bulletin disclaimer and definitions regarding your responsibilities for assessing potential impact of security vulnerabilities to your environment.

[{"Product":{"code":"ST3FR7","label":"IBM Storwize V7000"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"6.1","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1;6.2;6.3;6.4;7.1;7.2;7.3","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"STLM6B","label":"IBM Storwize V3500 (2071)"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.4;7.1;7.2;7.3","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"STLM5A","label":"IBM Storwize V3700 (2072)"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.4;7.1;7.2;7.3","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"STHGUJ","label":"IBM Storwize V5000"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1;7.2;7.3","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Product":{"code":"STPVGU","label":"SAN Volume Controller"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1;6.2;6.3;6.4;7.1;7.2;7.3","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
19 August 2022

UID

ssg1S1004987