IBM Support

Cache Destage Issue in SAN Volume Controller V6.1.0.4 and V6.1.0.5 Code May Result in an Incorrect Report that Host Data Has Been Written Correctly

Flashes (Alerts)


Abstract

An issue was introduced in V6.1.0.4 of the SAN Volume Controller code, which can result in host write operations failing to be written to disk, while the host that issued the write is informed that the write has completed successfully.

Content

Under high host workload conditions, if a node shutdown or reboot occurs, or a FlashCopy prepare command is issued, a situation can occur in which host writes that have entered the SAN Volume Controller node caches are not successfully written to backend physical disks.

When this occurs, the hosts that have submitted writes will have been informed that the writes had been successfully written at the point at which they had entered the node caches. The hosts will therefore not be aware that the writes have in fact ultimately failed to be committed to backend disks.

This failure to complete writes to physical disks is likely to result in an unreported condition where data is incompletely written to Volumes.

Fix

This issue is resolved in the V6.1.0.6 PTF release, available for download from the following URL:



http://www.ibm.com/support/docview.wss?uid=ssg1S4000954

[{"Product":{"code":"STPVGU","label":"SAN Volume Controller"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"6.1","Platform":[{"code":"","label":"SAN Volume Controller"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
25 September 2022

UID