Connecting Uninterrupted Power Supply ( UPS ) to Power8 Servers Using USB 2.0

Troubleshooting


Problem

How do I connect my UPS to the Power 8 sytem.

Resolving The Problem

New to Power 8 servers is using USB 2.0 to connect the UPS to the server.

Feature code ECCF (Part number 00FV631) - System Port Converter Cable for UPS

The ECCF is a converter cable that allows for communications from a UPS relay interface card to a service processor USB port. The server has two service processor USB 2.0 ports on the native I/O daughter card that are labeled 1 and 2. Either of these ports (1 or 2) can be used for the ECCF. Only one ECCF is allowed per server. The connectors on the ECCF include a male USB and a female 9-pin D-shell connector. The cable length is 1650 mm (65 inches).


Feature code ECCF and UPS Wiring
The cable can be connected to either USB port 1 or USB port 2 at any time. It is not necessary to IPL the server for the server to recognize the cable. The cable contains active electronics that tell the service processor that a UPS is attached. The UPS can provide status information (such as UPS on, UPS utility fail, UPS battery low, and UPS bypass) over the cable to the physical hypervisor for broadcast to all partitions.
http://www-01.ibm.com/support/knowledgecenter/POWER8/p8had/p8had_ups.htm?cp=POWER8%2F1-2-1-1-3

Note: The two service processor USB 2.0 ports that are labeled 1 and 2 correspond to location codes Un-P1-C1-T2 and Un-P1-C1-T3. See image below:

Power8_diagram
http://www-01.ibm.com/support/knowledgecenter/POWER8/p8ecs/p8ecs_82x_84x_loccodes.htm?cp=POWER8%2F1-4-5-0-1&lang=en)

[{"Product":{"code":"SGUQLB","label":"I\/O Enclosure Hardware"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Component":"Not Applicable","Platform":[{"code":"","label":"Power"}],"Version":"Version Independent","Edition":"Standard","Line of Business":{"code":"","label":""}},{"Product":{"code":"SGUQLB","label":"I\/O Enclosure Hardware"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Component":" ","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"","label":""}}]