MF65764 - OSP-DB *file restore diagnostic enhancement
PTF ( Program Temporary Fixes ) Cover letter
OSP-DB *file restore diagnostic enhancement
Pre/Co-Requisite PTF / Fix List
REQ LICENSED PTF/FIX LEVEL
TYPE PROGRAM RELEASE NUMBER MIN/MAX OPTION
---- -------- --------- ------- ------- ------
PRE 5770999 V7R3M0 MF65788 00/00 0000
NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels. This PTF may be a prerequisite
for future PTFs. By applying this PTF you authorize and agree to the
foregoing.
This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.
SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.
APAR Error Description / Circumvention
-----------------------------------------------
A restore of a saved database file may fail if the saved file
member (data space MI object) became too large. Only files with
very large LOB (CLOB, BLOB, DBLOB) could be affected.
CORRECTION FOR APAR MA47528 :
-----------------------------
This PTF has the ability to collect additional data during both
save and restore. There will be new vlogs generated in failure
conditions: vl060058B6, vl060058B7 & vl060058B8. If the file
member is too large to be saved or restored, the operation (save
or restore) will fail and generate the new vlogs. Saves will
fail with MSGCPF3795 and Error summary code C5CD.
CIRCUMVENTION FOR APAR MA47528 :
--------------------------------
None.
Activation Instructions
None.
Special Instructions
********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************
SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF MF61374 :
=================================================
If one or both of the PTFs for MA45275 or MA45104 have been installed
on a system when a table or physical file is saved, then BOTH of those
PTFs must also be installed on the system where the file is restored to
prevent the possibility of a restore failure. Specifically, some files
with variable length or LOB fields may be damaged during the restore if
the PTFs are not present. Because this may occur when restoring across
releases, PTFs for all releases are listed.
NOTE: One or both of the PTFs for MA45275 and MA45104 may be installed
on the restore system when a table or physical file is restored even if
the PTFs were not installed on the save system at the time of the save.
This includes saving a file from a system at one release and restoring
it to a system at a different release.
The PTFs for MA45275 are:
V7R1: MF62518
V7R2: MF62519
V7R3: MF61374
The PTFs for MA45104 are:
V7R1: MF61046
V7R2: MF61047
V7R3: MF60986
Default Instructions
THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.
Supersedes
PTF/FIX NO(S). APAR TITLE LINE
-------------- ------------------------------------------------------------
MF61374 LIC-DB Correct Save/Restore inconsistancy in Recycle index
MF60985 LIC-DB Correct Save/Restore inconsistancy in Recycle index
Summary Information
System.............................. | i |
Models.............................. | |
Release............................. | V7R3M0 |
Licensed Program............... | 5770999 |
APAR Fixed.......................... | View details for APAR MA47528 |
Superseded by:...................... | View fix details for PTF MF66576 |
Recompile........................... | N |
Library............................. | QSYS |
MRI Feature ........................ | NONE |
Cum Level........................... | C9311730 |
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.
Document information
More support for:
i family
Software version: V7R3M0
Operating system(s): OS/400
Reference #: MF65764
Modified date: 08 May 2019