Abstract

OSP-MSGMCH0601 in QLILIST when lib assoc space has incorrect
offset

Error Description

Program QLILIST is called to get a list of object names and    
descriptive information about objects in a library.  If a      
library's associated space has an incorrect offset field,      
program QLILIST attempts to use the incorrect offset field to  
access the object information repository (OIR) objects for the  
library.  A MCH0601 error occurs in program QLILIST using the  
incorrect offset field and then a function check (CPF9999)      
error.                                                          
                                                               
The following messages occur:                                  
MCH0601 - Space offset X'00000000' or X'0000000000000000' is    
outside current limit for object &1                            
CPF9999 - Function check. MCH0601 unmonitored by QLILIST at    
statement *N, instruction X'0C66'.                              

Problem Summary

****************************************************************
* PROBLEM: (SE69265) Licensed Program = 5770999                *
*           Damage Where Recovery is an IPL, Re-Install, or    *
*           Restore                                            *
****************************************************************
* USERS AFFECTED: All IBM i operating system users.            *
****************************************************************
* RECOMMENDATION: Apply PTF SI67501 for i 7.1.                 *
****************************************************************
                                                               
Program QLILIST is called to get a list of object names and    
descriptive information about objects in a library.  If a      
library's associated space has an incorrect offset field,      
program QLILIST attempts to use the incorrect offset field to  
access the object information repository (OIR) objects for the  
library.  A MCH0601 error occurs in program QLILIST using the  
incorrect offset field and then a function check (CPF9999)      
error.                                                          
                                                               
The following messages occur:                                  
MCH0601 - Space offset X'00000000' or X'0000000000000000' is    
outside current limit for object &1                            
CPF9999 - Function check. MCH0601 unmonitored by QLILIST at    
statement *N, instruction X'0C66'.                              

Problem Conclusion

Program QLILIST was corrected to handle a MCH0601 error which  
occurred when an incorrect offset value was used.  When an error
occurs on the library's associated space, program QLIRCLLI is  
called to recover or rebuild the library's associated space.    

Temporary Fix

                       *********                                
                       * HIPER *                                
                       *********                                

Comments

Circumvention


PTFs Available

R730 SI67501 PTF Cover Letter   8242

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... Yes
Component.................................. 5770SS1WM
Failing Module.......................... RCHMGR
Reported Release................... R730
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 September 2018