IBM Support

SE67813 - TCPIP-MSGMCH3802 TRCTCPAPP *TELNET/*VTAPI QTVxxxxxx spaces

 APAR (Authorized Program Analysis Report)

Abstract

TCPIP-MSGMCH3802 TRCTCPAPP *TELNET/*VTAPI QTVxxxxxx spaces

Error Description

TRCTCPAPP *TELNET running for long period causes jobs to        
receive MCH3802, stating message queue QTVTRC is full and not  
extendible.                                                    

Problem Summary

TRCTCPAPP *TELNET/*VTAPI jobs receive MCH3802, stating message  
queue QTVTRC is full and not extendible after 200 jobs are      
traced.                                                        
QTVxxxxxx *USRSPC objects are orphaned in QUSRSYS when the      
MCH3802 is encountered.                                        
The 200 job limit is insufficient for long running traces or    
cases where many VTAPI jobs are running.                        

Problem Conclusion

The number of Telnet trace spaces will be increased to 4096 for
the *TELNET/*VTAPI jobs traced by the TRCTCPAPP command.        
Message CPFB670 will be logged to QSYSOPR indicating which jobs
will not capture trace data when the new limit is reached for  
this trace session.  Active traces will continue until the      
TRCTCPAPP is ended.                                            
Once the TRCTCPAPP is ended, orphaned trace spaces can be      
cleaned up using a command like:                                
                                                               
DLTUSRSPC USRSPC(QUSRSYS/QTV*)                                  

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI65496 PTF Cover Letter   1000
R720 SI65502 PTF Cover Letter   7290
R730 SI65503 PTF Cover Letter   7283

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information